EasyPlus mini R13N Self-Monitoring Blood Glucose System User’s Manual Please read this User’s Manual thoroughly before using your blood glucos
Understanding Your Test Results …...31 Unusual Test Results ………………
11 Chapter 1: Understanding Your Meter EasyPlus mini R13N Blood Glucose Meter A. Month and date B. Test result C. Application of blood
12 The EasyPlus mini R13N Blood Glucose Test Strip and Accessories Blood Glucose Test Strip Lancing Device Test Strip BottleControl Solution
13 Setting the Time and Date — First Time Use Setting the current time and date in your meter is important if you intend to use the meter memory.
14 Using EasyPlus mini R13N Blood Glucose Test Strips Use only with EasyPlus mini R13N Blood Glucose Meter. Keep the test strips in their origin
15 Chapter 2: Control Solution Testing Why Run a Control Solution Test We recommend that you run the EasyPlus mini R13N Normal control solution test b
16 About The Control Solution Use only with EasyPlus mini R13N test strips. Write the date you opened the control solution bottle on the bottle
17 Running A Control Solution Test You need the meter, a test strip, and control solution 3. Place the meter on a flat surface, like a t
18 5. Squeeze the bottle until a tiny drop forms at the tip of the control solution cap. 6. Touch the drop to the Blood Collection Area a
19 Understanding Control Solution Test Results The label on your test strip bottle shows the acceptable ranges for the Control Solutions. The result y
Dear EasyPlus mini R13N SMBG System user, Thank you for choosing the EasyPlus mini R13N Self-Monitoring Blood Glucose (SMBG) System. We designed this
20 Troubleshooting Checks Action 9 Was the test strip exposed to open air for a long period of time? If yes, repeat the c
21 Chapter 3: Testing Your Blood Glucose Using the Lancing Device The best depth setting is the lowest number that draws enough blood for a test. T
22 Inserting a Lancet into the Lancing Device You must first load the lancet into the lancing device to get it ready for use. 1. Unscrew the C
23 1. Select 1-2 for soft or thin skin, 3 for average, and 4-5 for thick or calloused skin. 2. Lancing device and lancets are not
24 Running A Blood Glucose Test With Blood From Your Fingertips 1. Wash your hands with soap and warm water. Rinse and dry thoroughly.
25 5. Place the lancing device against the tip or side of your finger; press the trigger button to activate the lancing device. 6. Gently
26 Alternate Site Testing (Optional) Understanding Alternate Site Testing (AST)What is the advantage of AST? You have the option of testing other plac
27 Talk with your healthcare professional before you test with your palm or forearm. Do NOT ignore symptoms of high or low blood glucose. Fin
28 3. Press the trigger button to activate the lancing device. 4. Hold the device against forearm and increase pressure until the blood sample size i
29 2. Press and hold the device with one clear adjustable tip against the palm. 3. Press the trigger button to activate the lancing device. 4. Hold
Standard Accessories Your new EasyPlus mini R13N Blood Glucose meter and accessories work together to measure the amount of glucose in your blood. The
30 Discarding Used Lancets 1. Unscrew and remove the cap. 2. Without touching the used lancet, stick the lancet tip into its protective cover. 3
31 Understanding Your Test Results The EasyPlus mini R13N Blood Glucose test strips are plasma referenced and calibrated for easier comparison to lab
32 Symptoms of High or Low Blood Glucose Being aware of the symptoms of high or low blood glucose can help you understand your test results and deci
33 Comparing Your Meter Result to a Lab Result A common question is how the blood glucose results on your meter compare to the lab results. Your blood
34 Chapter 4: Meter Memory, Setup Memory, Storing Test Results Your meter stores a maximum of 360 test results with the time and date of the test. You
35 Viewing & Deleting Test Results You can review them at any time without inserting a test strip. 1. Press to review test results
36 Meter Memory You can review them at any time without inserting a test strip. 1. Press to review test results of 30 days in , ,
37 Chapter 5: Maintenance and Troubleshooting Inserting Battery The meter uses one CR2032 Lithium Battery. Batteries will normally last for more than
38 Cleaning Your Meter Caring for your EasyPlus mini R13N SMBG system does not require special cleaning. Please keep the meter free of dirt, dust, b
39 Maintenance And Testing Your meter needs little or no maintenance with normal use. It automatically tests its own systems every time you turn it on
Why is it so important to test blood glucose regularly? Testing your blood glucose regularly can make a big difference in how you manage your diabet
40 Screen Messages and Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, please contact your local d
41 Message What it means? What to do? System error There may be a problem with the meter. Replace the batteries first. If Err 001 appears again,
42 Message What it means? What to do? The test result is lower than 20 mg/dL. This may require immediate treatment according to your healthcare pr
43 Chapter 6: Technical Information Specifications Brand name EasyPlus mini R13N Blood Glucose Meter Range 20~630 mg/dL Response time 5 seconds Me
44 Device Information EasyPlus mini R13N SMBG System, EasyPlus mini R13N Blood Glucose Test Strips, EasyPlus mini R13N Blood Glucose Meter. Manufactu
45 Obelis s.a. 34, Av. de Tervuren, bte 44, B-1040 Brussels, Belgium TEL:(32) 2.732.59 54 FAX:(32) 2.732.60 03 E-mail: [email protected] Lancing
Important Information About Your New Meter EasyPlus mini R13N blood glucose meter is designed and approved for testing fresh capillary whole bloo
acid and methyldopa may affect results. Incorrect results may occur when performing the test. If you believe you are not feeling well, please conta
Health-Related Information If you are very dehydrated, urinating frequently, have low blood pressure, in shock or hyperosmolar hyperglycemic nonk