EPS Bio Technology EasyPlus mini Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non EPS Bio Technology EasyPlus mini. EPS Bio Technology EasyPlus mini User`s manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - User’s Manual

EasyPlus mini Self-Monitoring Blood Glucose System User’s Manual Please read this User’s Manual thoroughly before using your blood glucose met

Page 2 - Intended Use

10 Chapter 1: Understanding Your Meter The EasyPlus mini Blood Glucose Meter The Overview of the Display Meaning A Year, month and

Page 3 - Optional Accessories

11 The Overview of the Meter: A. Manufacturer information B. Smart Jog Wheel C. Serial number D. Display E. Anti-Slippery Pad

Page 4 - Do you need Help?

12 Setting The Time and Date—First Time Use Setting the current time and date in your meter is important if you use the meter memory or if you want to

Page 5

13 4. Press inwards and release the wheel to set the month. The date will then flash. Repeat step 3 to set the date.5. Press inwards and re

Page 6

14 Checking Your System A new check strip is included with your meter. 1. Make sure your check strip is inserted. The meter will turn on automatic

Page 7 - Health-Related Information

15 Coding Your Meter A new Code Card is inside each new box of test strips. Code your meter every time you open a new box of test strips. 1

Page 8 - Table of Content

16 Using EasyPlus mini Blood Glucose Test Strip  Use only with EasyPlus mini Blood Glucose Meter.  Code your meter and run a control test every time

Page 9

17 Chapter 2: Control Solution Testing Why Run A Control Solution Test Running a control test lets you know that your meter and test strips are workin

Page 10

18 About The Control Solution  Use only with EasyPlus mini test strips.  Write the date you opened the bottle on the bottle label. The control solut

Page 11

19 Running A Control Solution Test You need the meter, a test strip, and control solution 2. If you can’t see the code number, take the

Page 12

Dear EasyPlus mini SMBG System Owner, Thank you for using the EasyPlus mini Self-Monitoring Blood Glucose (SMBG) System. We designed this system to be

Page 13

20 3. Place the meter on a flat surface, like a table.4. Remove the control solution bottle cap and wipe the tip of the bottle with a tiss

Page 14 - Checking Your System

21 6. A result appears on the display. Don’t remove the test strip yet. Check if the reading falls within the range printed on the test strip

Page 15 - Coding Your Meter

22 Understanding Control Test Results The label on your test strip bottle shows the acceptable ranges for the Control Solution. The result you get s

Page 16

23 Troubleshooting Checks Action  Was the test strip exposed to open air for a long period of time? Repeat the c

Page 17

24 Chapter 3: Testing Your Blood Glucose Using The Lancing Device  The best depth setting is the lowest number that draws enough blood for a test. Tr

Page 18 - About The Control Solution

25 Inserting A Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use. 1. Take the ca

Page 19

26 3. Recap the front cap.4. Select the desired penetration depth. Note: Select 1-3 for soft or thin skin, 4-5 for average, and 6-8 for thi

Page 20

27 5. Pull on the sliding barrel of the lancing device until it clicks and then release. Now the lancing device is ready. Do not

Page 21

28 Running A Blood Glucose Test With Blood From Your Fingertip 1. Wash your hands with soap and warm water. Rinse and dry thoroughly. 2

Page 22

29 4. Swab the blood collection area on your finger with an alcohol swab. Please wait at least 5 seconds until the intended area is dry an

Page 23

Standard Accessories Your new EasyPlus mini Blood Glucose meter and accessories work together to measure the amount of glucose in your blood. The syst

Page 24

30 7. Gently squeeze your finger to assist the flow of blood. This helps you get a blood drop. Touch the drop to the tip of the tran

Page 25 - 1. Take the cap off

31 Alternative Site Testing (AST) Understanding Alternative Site Testing Alternative site results may differ from the fingertip when glucose lev

Page 26 - 3. Recap the front cap

32 Caution:  Talk with your healthcare professional before you test palm or forearm.  Do NOT ignore symptoms of high or lo

Page 27

33 1. This pictures shows areas where alternative site testing is allowed. 2. Massage the puncture area of palm for a few seconds. Running A Blood G

Page 28

34 4. Press the trigger button to activate the lancing device. 5. Hold the device against palm and increase pressure until the blood sample size is su

Page 29

35 1. Massage the puncture area of forearm for a few seconds. 2. Press and hold the device with one clear adjustable tip against the forearm. 3. Press

Page 30

36 Discarding Used Lancets 1. Unscrew and remove the adjustable cap. Without touching the used lancet, stick the lancet tip into its prote

Page 31 - Fingertip test only:

37 Expected Values* The EasyPlus mini Blood Glucose test strips are whole-blood referenced and calibrated for easier comparison to lab results. The no

Page 32 - Caution:

38 Symptoms Of High Or Low Blood Glucose Being aware of the symptoms of high or low blood glucose can help you understand your test results and deci

Page 33

39 Comparing Your Meter Result To A Lab Result A common question is how the blood glucose results on your meter compare to the lab results. Your blood

Page 34

Why is it so important to test blood glucose regularly? Testing your blood glucose regularly can make a big difference in how you manage your diabet

Page 35

40 Chapter 4: Meter Memory, Setup Memory, Storing Test Results Your meter stores a maximum of 480 test results with the time and date of the test. You

Page 36 - Discarding Used Lancets

41 Viewing & Deleting Test Results 1. Press inwards and hold the wheel until turning the meter on. 2. Push the wheel up or down

Page 37 - Unusual Test Results

42 Setting The Alarm The meter can set up to 4 alarms, allowing you to control your test times according to your requirements. he 1. Press

Page 38

43 5. If the time is set at 12:00 AM, push up or down twelve times to set at "12". Press inwards to confirm. 7. If you don

Page 39

44 8. You can then set up other alarms fitting as wanted. Please repeat the step 1 to 7, and finally press inwards to confirm the setti

Page 40 - Memory, Storing Test Results

45 Chapter 5: Maintenance and Troubleshooting Installing Batteries The meter uses two alkaline 1.5V (AAA) batteries. Batteries will normally last for

Page 41

46 Cleaning Your Meter Caring for your EasyPlus mini SMBG system does not require special cleaning. Please keep the meter free of dirt, dust, bloods

Page 42 - Setting The Alarm

47 Maintenance And Testing Your meter needs little or no maintenance with normal use. It automatically tests its own systems every time you turn

Page 43

48 Screen Messages And Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, call our Customer Service T

Page 44

49 System fault Action: Replace the batteries first. If 001 ERROR appears again, please call Customer Service toll-free 1-866-203-2761. Syst

Page 45 - Installing Batteries

Important Information About Your New Meter  EasyPlus mini blood glucose meter is designed and approved for testing fresh capillary whole blood samp

Page 46 - Cleaning Your Meter

50 The "Ht" and thermometer icon appears. Temperature is too high, outside the required range of 50°F ~104°F (10°C ~40°C). This ale

Page 47 - Cleaning Your Lancing Device

51 Test result is higher than 600 mg/dL. Action: Test again. If the result is still the same, please contact your healthcare professional. Th

Page 48

52 Chapter 6: Technical Information Specifications Brand name EasyPlus mini Blood Glucose Meter Range 20~600 mg/dL Response time 5 seconds Memory

Page 49

53 Limitation The test strips are used for fresh capillary whole blood samples. 1. DO NOT use neonate blood sample. 2. Extreme humidity may affect

Page 50

54 10. Critically ill patients should not be tested with home-use blood glucose meters. 11. Interfering Substances depend on the concentration. The

Page 51

55 Device Information EasyPlus mini SMBG System, EasyPlus mini Blood Glucose Test Strips, EasyPlus mini Blood Glucose Meter. Manufacturer: EPS BIO TE

Page 52 - Specifications

56 Lancet Meets the requirements of MDD 93/42/EEC Manufacturer: SAE HAN MEDICAL CORP. # 700-113 PUB GOT-DONG, IL SAN-GU, GOYANG-CITY, KYUNGGI-DO, KOR

Page 53 - Limitation

 Warning for potential biohazard: Healthcare professionals using this system on multiple patients should be aware that all products or objects that c

Page 54

Health-Related Information  If you are experiencing dehydration, frequent urination, low blood pressure, shock or hyperosmolar hyperglycemic nonket

Page 55 - Device Information

Table of Content Chapter 1: Understanding Your Meter ….......

Page 56 - Warranty

Unusual Test Results ……………………………...........…………………………………...37 Symptoms Of High Or Low Blood Glucose …..... ...